Customization: | Available |
---|---|
Max.Head: | 30-50m |
Max.Capacity: | 100-200 L/min |
Still deciding? Get samples of US$ 300/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PRODUCT OVERVIEW
This intelligent frequency conversion water supply equipment consists of PID variable frequency inverter with latest property and pump, which can adjust automaticlly to meet customers' requirements with constant pressure. As the water supply network keep the constant pressure, the whole water supply system keeps energy-efficient all the time. Water suuply with frequency conversion automaticlly adjust the speed of each pump or the input / exit of some pumps, which is the ideal way to keep the pressure of water supply network constant with sample operation.
RANGE OF APPLICATION
Household water supply: high building, residential quarter, villa etc.
Public place: hospital, school, gymnasium, golf course, airport, etc.
Commercial building: hotel, office building, department store, bathing place, etc.
Irrigation: park, playground, orchard, farm, etc.
Manufacturing industry: manufacturing, washing device, food industry, plant, etc.
ADVANTAGE
Solve the problem of low water pressure:
It adopts constant-pressure variable frequency water supply to keep the pressure in the whole building constant.
Avoid making water pollution by using attic tank, which eliminate the source of water pollution.
Reduce the cost of building and increase space:
Removing traditional attic tank reduces the construction stress. Its struction is sample and cost is less.
Save power and reduce space:
It can save 30% power compared with regular water supply equipment. And this equipment occupies less space and owns sampler installation which can reduce the time for a project.
Multi-pump frequency conversion: every pump is equipped with a frequency converter. multi-pumps change frequency in the meantime.
PERFORMANCE FEATURE
Full automatic control, constant water pressure;
Set up the pressure directly in the manipulator;
Built-in pressure sensor or flow sensor, water level switch with signal interface;
P.I.D control mode, automatic monitoring (get into dormant state when there is no water);
Get the function of automatic alternate without PLD;
Start up automaticlly after no power or low water level recover;
Start-stop pf cooling fan is controlled by internal temperature, which can prolong the life-span of cooling fan;
When multi pumps operate coordinately, it will change the main pump regularly, which can blance the work time of each pump in case of wear and rust of each pump;
It can be used in the cold area with its anti-freezing function;
Adequate monitoring of operation and thorough protection function of motor, sample operation, small volume.
Model pictures:
PERFORMANCE PARAMETER
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | |||
IQ1 | BW(J)(T)2-20(D) | 0.37 | 25 | 8/6 |
HEAD (m) |
19 | 18 | 16 | 14 | 13 | 11 | 9 | |||
9BW(J)(T)2-30(D) | 0.55 | 25 | 8/6 | 28 | 27 | 24 | 21 | 20 | 17 | 14 | |||||
BW(J)(T)2-40(D) | 0.55 | 25 | 8/6 | 36 | 34 | 32 | 28 | 26 | 23 | 17 | |||||
BW(J)(T)2-050(D) | 0.55 | 25 | 8/6 | 46 | 43 | 40 | 35 | 33 | 28 | 22 | |||||
BW(J)(T)2-60(D) | 0.75 | 25 | 8/6 | 54 | 50 | 48 | 42 | 38 | 33 | 25 | |||||
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
1 | 2 | 3 | 4 | 5 | 6 | 7 | |||
IQ1 | BW(J)(T)4-20(D) |
0.37 |
32/25 |
8/6 |
HEAD (m) |
19 | 18 | 16 | 15 | 13 | 10 | 7 | |||
BW(J)(T)4-30(D) | 0.55 | 32/25 | 8/6 | 28 | 27 | 24 | 22 | 19 | 15 | 10 | |||||
BW(J)(T)4-40(D) | 0.55 | 32/25 | 8/6 | 38 | 36 | 32 | 30 | 26 | 20 | 14 | |||||
BW(J)(T)4-50(D) | 0.55 | 32/25 | 8/6 | 46 | 44 | 41 | 38 | 32 | 26 | 20 | |||||
BW(J)(T)4-60(D) | 0.75 | 32/25 | 8/6 | 55 | 53 | 50 | 45 | 37 | 31 | 26 | |||||
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
5 | 6 | 7 | 8 | 9 | 10 | 11 | |||
IQ1 | BW(J)(T)8-10(D) | 0.75 | 40/32 | 8/6 |
HEAD (m) |
9.5 | 9.3 | 9 | 8.5 | 7.5 | 6.5 | 5.5 | |||
BW(J)(T)8-20(D) | 0.75 | 40/32 | 8/6 | 19 | 18.5 | 18 | 17 | 15 | 13 | 11 | |||||
BW(J)(T)8-30(D) | 1.1 | 40/32 | 8/6 | 29 | 28 | 27 | 25.5 | 22.5 | 20 | 17.5 | |||||
BW(J)(T)8-40(D) | 1.5 | 40/32 | 8/6 | 39 | 38 | 36 | 34 | 30 | 26.5 | 22.5 | |||||
BW(J)(T)8-50(D) | 2.2 | 40/32 | 8/6 | 49 | 47 | 45 | 42.5 | 38 | 33.5 | 28 | |||||
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
IQ1 |
BW(J)(T)12-10(D) |
0.75 |
40 |
18/6 |
HEAD (m) |
11.5 |
11.2 |
11 |
10.5 |
10 |
9.5 |
9 |
8 | 7 | 6 |
BW(J)(T)12-20(D) | 1.2 | 40 | 18/6 | 23 | 22.5 | 22 | 21.5 | 20.5 | 19.5 | 18.5 | 17 | 15.5 | 13 | ||
BW(J)(T)12-30(D) | 1.8 | 40 | 18/6 | 35 | 34.5 | 33.5 | 32.5 | 31 | 29.5 | 28 | 26 | 23.5 | 20 | ||
BW(J)(T)12-40(D) | 2.4 | 40 | 18/6 | 47 | 46 | 45 | 43.5 | 41.5 | 39.5 | 37.5 | 35 | 31.5 | 27.5 | ||
BW(J)(T)12-50 | 3.0 | 40 | 18/6 | 60 | 58 | 56.5 | 55 | 52.5 | 50 | 47 | 44 | 40 | 35 | ||
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | ||
IQ1 |
BW(J)(T)16-10(D) |
1.1 |
50 |
18/6 |
HEAD (m) |
12.5 | 12 | 11.5 | 10.5 | 10 | 9 | 7.5 | 6.5 | ||
BW(J)(T)16-20(D) | 2.2 | 50 | 18/6 | 25.5 | 24 | 23 | 22 | 21 | 19 | 17 | 14.5 | ||||
BW(J)(T)16-30 | 3.0 | 50 | 18/6 | 38.5 | 37 | 36 | 34 | 32 | 30 | 27 | 23 | ||||
BW(J)(T)16-40 | 4.0 | 50 | 18/6 | 51.5 | 50.5 | 49 | 46 | 43 | 40.5 | 36 | 31.5 | ||||
CATEGORY | MODEL |
POWER OF PUMP (KW) |
INLET/OUTLET TUBE (DN) |
PRESSURE TANK (L/bar) |
FLOW (m³/h) |
10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 |
IQ1 | BW(J)(T)20-10(D) | 1.1 | 50 | 18/6 |
HEAD (m) |
12.5 | 12 | 11.5 | 11 | 10.5 | 9.5 | 8.5 | 7.5 | 6.5 | 5.5 |
BW(J)(T)20-20(D) | 2.2 | 50 | 18/6 | 25.5 | 24.5 | 24 | 23 | 22 | 21 | 20 | 18 | 16 | 13.5 | ||
BW(J)(T)20-30 | 4.0 | 50 | 18/6 | 38 | 37.5 | 37 | 36 | 35 | 33 | 31 | 28 | 25 | 22 | ||
BW(J)(T)20-40 | 4.4 | 50 | 18/6 | 51 | 50 | 49 | 48 | 47 | 44.5 | 41.5 | 37.5 | 33.5 | 30 |
FAQ
Q: What is your MOQ of this item?
A: Our MOQ is a full 20ft container, first time cooperation, we accept trial order to check quality.
Q: Is it acceptable to make customers' own brand?
A: Sure, we can do OEM.
Q: What are your payment terms?
A: 30% T/T deposit, 70% against documents, or L/C at sight.
Q: How long is your warranty?
A: One year!
Q: What is the delivery time?
A: 25-30 days after receiving your L/C or T/T deposit.
Contacting information:
TAIZHOU QIANTAO PUMPS CO.,LTD(CHIMP)
TEL: 0086-576-86330365
FAX: 0086-576-86334238